Half-Cell Potential Test
NABL ACCREDITED PARAMETER (TC-7290)FACILITY: CENTRAL TESTING LAB JAIPUR
Rebar corrosion probability with copper sulphate electrode.
Electrochemical technique using a copper-copper sulphate reference electrode to measure the probability of active rebar corrosion in reinforced concrete structures.
Certified Test Parameters Included
Measurements & Test Procedures
•Rebar corrosion probability
•Copper sulphate electrode method
•Bridges, buildings & slabs
•As per IS 516 (Part 5/Sec 2)
PROJECT ENGAGEMENT
HAVE AN ENGINEERING CHALLENGE?
Tell us about your project, site condition, testing requirement or engineering challenge. Our team can help identify the appropriate investigation, testing or engineering approach.
Direct Hotline
+91 81144 28016Engineering Desk
info@namotech.inTesting Accreditation
NABL Cert. TC-7290