Investigation Mandate

To verify the structural integrity and load capacity of installed piles — through Pile Integrity Test (PIT), Vertical Load Test and Lateral Load Test — ensuring foundation safety before superstructure construction.

What We Deliver On Site

Pile Integrity Test (PIT) — low strain
Vertical Pile Load Test (Static)
Lateral Pile Load Test
Cyclic Vertical Load Test
Pull-out (Uplift) Test
Dynamic Pile Load Test (PDA)
Cross-hole Sonic Logging (CSL)
As per IS 2911 (Part 4)

Field & Laboratory Methodology

PIT: Low-strain hammer impact → echo signal recorded → defect/length analysis. Static Load Test: Kentledge or anchor pile reaction → load applied in 50%, 100%, 150% increments → settlement monitoring → ultimate vs safe load determination per IS 2911.

Certified Outputs & Deliverables

Pile Test Report (IS 2911 format)
Load vs settlement curves
PIT signal analysis (echo logs)
Integrity defect localization
Safe load capacity certificate
Recommendations for design changes