Building Rehabilitation & Restrengthening

Specialist structural restoration, capacity upgradation, and seismic retrofitting for hospitals, commercial complexes, hotels, residential societies, and institutional towers across India. From NDT diagnostic surveys and STAAD/ETABS retrofit engineering to on-site execution supervision — extending building service life by 25–50 years.

Audited Portfolio100+ Buildings
Governing StandardsIS 13935 · IS 456
Testing LabNABL TC-7290
Flagship ProjectBIDA Bhiwadi (₹5+ Cr)

Common Building Distress Modes We Diagnose & Rectify

Based on audit records of 100+ multi-storey structures across India, these recurring distress mechanisms threaten occupant safety and asset integrity if left untreated.

Concrete Carbonation

Atmospheric CO₂ has reduced concrete alkalinity, initiating active reinforcement corrosion in 25+ year old structures.

Rebar Corrosion & Spalling

Chloride ingress, water seepage, and inadequate cover induce expansion stresses, cracking and concrete spalling.

Seismic Non-Compliance

Pre-2002 buildings designed under older IS 1893 lack ductile detailing and lateral stiffness mandated for modern seismic zones.

Foundation Settlement

Differential settlement, soil moisture shifts, and increased floor loads cause masonry cracking and structural distortion.

Moisture Seepage

Water ingress from terraces, expansion joints, and external façades degrades load-bearing concrete and steel rebar.

Capacity Upgrades

Change of building occupancy, commercial floor additions, or heavy equipment installations requiring column/slab strengthening.

Building Structures We Specialize In

Tailored structural engineering protocols accommodating operational continuity, sensitive occupants, and strict aesthetic guidelines.

Hospitals & Healthcare

Critical healthcare facilities, medical colleges, and specialty clinics requiring non-disruptive retrofitting.

Hotels & Hospitality

Luxury properties, business hotels, and resort complexes demanding fast-track structural life extension.

Commercial & IT Parks

Corporate headquarters, shopping malls, IT campuses, and commercial high-rises.

Residential Complexes

Multi-storey housing societies, RWA apartment towers, and gated residential communities.

Institutional Campuses

Universities, research centers, schools, and government administrative headquarters.

High-Rise Towers

Mid-rise to high-rise mixed-use developments with complex lateral wind and seismic demands.

Building Restrengthening & Rehabilitation Services

Explore dedicated specification detail pages for each structural intervention discipline.

01

Condition Assessment for Buildings

Complete structural health evaluation

To establish the true structural health of a building through systematic survey, NDT and analysis — the diagnostic foundation for any rehabilitation strategy.

02

Structural Strengthening Design

Column, beam, slab & foundation retrofit

To design targeted strengthening for deficient structural members — restoring or enhancing capacity using jacketing, FRP, section enlargement and modern retrofit techniques.

03

Seismic Retrofitting of Buildings

Earthquake resistance upgrade for older buildings

To upgrade the seismic resistance of existing and older buildings to current code levels — through evaluation and retrofit measures that reduce earthquake risk.

04

Crack Repair & Waterproofing

Structural & non-structural crack treatment

To diagnose and treat cracks and water ingress — restoring integrity and durability through the right injection, sealing and waterproofing systems.

05

Corrosion Control & Rebar Protection

Stopping rebar corrosion

To arrest reinforcement corrosion and protect concrete — extending service life through assessment, treatment and inhibitor / cathodic protection systems.

06

PMC for Building Rehabilitation

On-site supervision & execution

To manage and supervise building rehabilitation execution — ensuring repairs are carried out to specification, safely and on schedule.

BIDA Bhiwadi Rehabilitation
STATUTORY GOVERNMENT REHAB

BIDA Bhiwadi — 18 EWS Housing Blocks Rehabilitation

Complete structural assessment and multi-disciplinary rehabilitation of 18 Economically Weaker Section (EWS) residential blocks under the Bhiwadi Integrated Development Authority (BIDA). Scope encompassed comprehensive non-destructive testing (NDT), structural strengthening design, column RCC jacketing, carbon-fiber (CFRP) confinement, and execution project management consultancy.

18EWS Blocks
₹5+ CrProject Value
DeliveredCode Compliant
VIEW ALL CASE STUDIES
PROJECT ENGAGEMENT

HAVE AN ENGINEERING CHALLENGE?

Tell us about your project, site condition, testing requirement or engineering challenge. Our team can help identify the appropriate investigation, testing or engineering approach.

Direct Hotline
+91 81144 28016
Engineering Desk
info@namotech.in
Testing Accreditation
NABL Cert. TC-7290